"""Provides methods to configure the Chp measurement."""
import functools
import nirfmxspecan.attributes as attributes
import nirfmxspecan.enums as enums
import nirfmxspecan.errors as errors
import nirfmxspecan.internal._helper as _helper
def _raise_if_disposed(f):
"""From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""
@functools.wraps(f)
def aux(*xs, **kws):
meas_obj = xs[0] # parameter 0 is 'self' which is the measurement object
if meas_obj._signal_obj.is_disposed:
raise Exception("Cannot access a disposed SpecAn signal configuration")
return f(*xs, **kws)
return aux
[docs]
class ChpConfiguration(object):
"""Provides methods to configure the Chp measurement."""
def __init__(self, signal_obj):
"""Provides methods to configure the Chp measurement."""
self._signal_obj = signal_obj
self._session_function_lock = signal_obj._session_function_lock
self._interpreter = signal_obj._interpreter
[docs]
@_raise_if_disposed
def get_measurement_enabled(self, selector_string):
r"""Gets whether to enable the CHP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is FALSE.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (bool):
Specifies whether to enable the CHP measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_ENABLED.value
)
attr_val = bool(attr_val)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_measurement_enabled(self, selector_string, value):
r"""Sets whether to enable the CHP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is FALSE.
Args:
selector_string (string):
Pass an empty string.
value (bool):
Specifies whether to enable the CHP measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_MEASUREMENT_ENABLED.value,
int(value),
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_span(self, selector_string):
r"""Gets the frequency range around the center frequency, to acquire for the measurement. This value is expressed in
Hz.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1 MHz.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the frequency range around the center frequency, to acquire for the measurement. This value is expressed in
Hz.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_SPAN.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_span(self, selector_string, value):
r"""Sets the frequency range around the center frequency, to acquire for the measurement. This value is expressed in
Hz.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1 MHz.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the frequency range around the center frequency, to acquire for the measurement. This value is expressed in
Hz.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_SPAN.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_number_of_carriers(self, selector_string):
r"""Gets the number of carriers.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the number of carriers.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_CARRIERS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_number_of_carriers(self, selector_string, value):
r"""Sets the number of carriers.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the number of carriers.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_CARRIERS.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_carrier_frequency(self, selector_string):
r"""Gets the center frequency of the carrier, relative to the RF
:py:attr:`~nirfmxspecan.attributes.AttributeID.CENTER_FREQUENCY`. This value is expressed in Hz.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the center frequency of the carrier, relative to the RF
:py:attr:`~nirfmxspecan.attributes.AttributeID.CENTER_FREQUENCY`. This value is expressed in Hz.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_CARRIER_FREQUENCY.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_carrier_frequency(self, selector_string, value):
r"""Sets the center frequency of the carrier, relative to the RF
:py:attr:`~nirfmxspecan.attributes.AttributeID.CENTER_FREQUENCY`. This value is expressed in Hz.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the center frequency of the carrier, relative to the RF
:py:attr:`~nirfmxspecan.attributes.AttributeID.CENTER_FREQUENCY`. This value is expressed in Hz.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_CARRIER_FREQUENCY.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_carrier_integration_bandwidth(self, selector_string):
r"""Gets the frequency range, over which the measurement integrates the power. This value is expressed in Hz.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is 1 MHz.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the frequency range, over which the measurement integrates the power. This value is expressed in Hz.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string,
attributes.AttributeID.CHP_CARRIER_INTEGRATION_BANDWIDTH.value,
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_carrier_integration_bandwidth(self, selector_string, value):
r"""Sets the frequency range, over which the measurement integrates the power. This value is expressed in Hz.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is 1 MHz.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the frequency range, over which the measurement integrates the power. This value is expressed in Hz.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string,
attributes.AttributeID.CHP_CARRIER_INTEGRATION_BANDWIDTH.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_carrier_rrc_filter_enabled(self, selector_string):
r"""Gets whether to apply the root-raised-cosine (RRC) filter on the acquired channel before measuring the channel
power.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is **False**.
+--------------+----------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+====================================================================================================+
| False (0) | The channel power of the acquired channel is measured directly. |
+--------------+----------------------------------------------------------------------------------------------------+
| True (1) | The measurement applies the RRC filter on the acquired channel before measuring the channel power. |
+--------------+----------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpCarrierRrcFilterEnabled):
Specifies whether to apply the root-raised-cosine (RRC) filter on the acquired channel before measuring the channel
power.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_CARRIER_RRC_FILTER_ENABLED.value
)
attr_val = enums.ChpCarrierRrcFilterEnabled(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_carrier_rrc_filter_enabled(self, selector_string, value):
r"""Sets whether to apply the root-raised-cosine (RRC) filter on the acquired channel before measuring the channel
power.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is **False**.
+--------------+----------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+====================================================================================================+
| False (0) | The channel power of the acquired channel is measured directly. |
+--------------+----------------------------------------------------------------------------------------------------+
| True (1) | The measurement applies the RRC filter on the acquired channel before measuring the channel power. |
+--------------+----------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpCarrierRrcFilterEnabled, int):
Specifies whether to apply the root-raised-cosine (RRC) filter on the acquired channel before measuring the channel
power.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpCarrierRrcFilterEnabled else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_CARRIER_RRC_FILTER_ENABLED.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_carrier_rrc_filter_alpha(self, selector_string):
r"""Gets the roll-off factor of the root-raised-cosine (RRC) filter.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is 0.1.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the roll-off factor of the root-raised-cosine (RRC) filter.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_CARRIER_RRC_FILTER_ALPHA.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_carrier_rrc_filter_alpha(self, selector_string, value):
r"""Sets the roll-off factor of the root-raised-cosine (RRC) filter.
Use "carrier<*n*>" as the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute.
The default value is 0.1.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the roll-off factor of the root-raised-cosine (RRC) filter.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string,
attributes.AttributeID.CHP_CARRIER_RRC_FILTER_ALPHA.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_rbw_filter_auto_bandwidth(self, selector_string):
r"""Gets whether the measurement computes the resolution bandwidth (RBW).
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **True**.
+--------------+-------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=========================================================================+
| False (0) | The measurement uses the RBW that you specify in the CHP RBW attribute. |
+--------------+-------------------------------------------------------------------------+
| True (1) | The measurement computes the RBW. |
+--------------+-------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpRbwAutoBandwidth):
Specifies whether the measurement computes the resolution bandwidth (RBW).
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH.value
)
attr_val = enums.ChpRbwAutoBandwidth(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_rbw_filter_auto_bandwidth(self, selector_string, value):
r"""Sets whether the measurement computes the resolution bandwidth (RBW).
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **True**.
+--------------+-------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=========================================================================+
| False (0) | The measurement uses the RBW that you specify in the CHP RBW attribute. |
+--------------+-------------------------------------------------------------------------+
| True (1) | The measurement computes the RBW. |
+--------------+-------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpRbwAutoBandwidth, int):
Specifies whether the measurement computes the resolution bandwidth (RBW).
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpRbwAutoBandwidth else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_rbw_filter_bandwidth(self, selector_string):
r"""Gets the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired signal, when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is
expressed in Hz.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 10 kHz.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired signal, when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is
expressed in Hz.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_rbw_filter_bandwidth(self, selector_string, value):
r"""Sets the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired signal, when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is
expressed in Hz.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 10 kHz.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the bandwidth of the resolution bandwidth (RBW) filter used to sweep the acquired signal, when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is
expressed in Hz.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string,
attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_rbw_filter_type(self, selector_string):
r"""Gets the shape of the digital resolution bandwidth (RBW) filter.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Gaussian**.
+---------------+----------------------------------------------------+
| Name (Value) | Description |
+===============+====================================================+
| FFT Based (0) | No RBW filtering is performed. |
+---------------+----------------------------------------------------+
| Gaussian (1) | An RBW filter with a Gaussian response is applied. |
+---------------+----------------------------------------------------+
| Flat (2) | An RBW filter with a flat response is applied. |
+---------------+----------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpRbwFilterType):
Specifies the shape of the digital resolution bandwidth (RBW) filter.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_TYPE.value
)
attr_val = enums.ChpRbwFilterType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_rbw_filter_type(self, selector_string, value):
r"""Sets the shape of the digital resolution bandwidth (RBW) filter.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Gaussian**.
+---------------+----------------------------------------------------+
| Name (Value) | Description |
+===============+====================================================+
| FFT Based (0) | No RBW filtering is performed. |
+---------------+----------------------------------------------------+
| Gaussian (1) | An RBW filter with a Gaussian response is applied. |
+---------------+----------------------------------------------------+
| Flat (2) | An RBW filter with a flat response is applied. |
+---------------+----------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpRbwFilterType, int):
Specifies the shape of the digital resolution bandwidth (RBW) filter.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpRbwFilterType else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_TYPE.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_rbw_filter_bandwidth_definition(self, selector_string):
r"""Gets the bandwidth definition that you use to specify the value of the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH` attribute.
The default value is **3dB**.
+---------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+===============+==========================================================================================================================+
| 3dB (0) | Defines the RBW in terms of the 3 dB bandwidth of the RBW filter. When you set the CHP RBW Filter Type attribute to FFT |
| | Based, RBW is the 3 dB bandwidth of the window specified by the CHP FFT Window attribute. |
+---------------+--------------------------------------------------------------------------------------------------------------------------+
| Bin Width (2) | Defines the RBW in terms of the spectrum bin width computed using an FFT when you set the CHP RBW Filter Type attribute |
| | to FFT Based. |
+---------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpRbwFilterBandwidthDefinition):
Specifies the bandwidth definition that you use to specify the value of the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH` attribute.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH_DEFINITION.value,
)
attr_val = enums.ChpRbwFilterBandwidthDefinition(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_rbw_filter_bandwidth_definition(self, selector_string, value):
r"""Sets the bandwidth definition that you use to specify the value of the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH` attribute.
The default value is **3dB**.
+---------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+===============+==========================================================================================================================+
| 3dB (0) | Defines the RBW in terms of the 3 dB bandwidth of the RBW filter. When you set the CHP RBW Filter Type attribute to FFT |
| | Based, RBW is the 3 dB bandwidth of the window specified by the CHP FFT Window attribute. |
+---------------+--------------------------------------------------------------------------------------------------------------------------+
| Bin Width (2) | Defines the RBW in terms of the spectrum bin width computed using an FFT when you set the CHP RBW Filter Type attribute |
| | to FFT Based. |
+---------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpRbwFilterBandwidthDefinition, int):
Specifies the bandwidth definition that you use to specify the value of the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH` attribute.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpRbwFilterBandwidthDefinition else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH_DEFINITION.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_sweep_time_auto(self, selector_string):
r"""Gets whether the measurement computes the sweep time.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **True**.
+--------------+----------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+========================================================================================+
| False (0) | The measurement uses the sweep time that you specify in the CHP Sweep Time attribute. |
+--------------+----------------------------------------------------------------------------------------+
| True (1) | The measurement calculates the sweep time based on the value of the CHP RBW attribute. |
+--------------+----------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpSweepTimeAuto):
Specifies whether the measurement computes the sweep time.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_AUTO.value
)
attr_val = enums.ChpSweepTimeAuto(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_sweep_time_auto(self, selector_string, value):
r"""Sets whether the measurement computes the sweep time.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **True**.
+--------------+----------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+========================================================================================+
| False (0) | The measurement uses the sweep time that you specify in the CHP Sweep Time attribute. |
+--------------+----------------------------------------------------------------------------------------+
| True (1) | The measurement calculates the sweep time based on the value of the CHP RBW attribute. |
+--------------+----------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpSweepTimeAuto, int):
Specifies whether the measurement computes the sweep time.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpSweepTimeAuto else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_AUTO.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_sweep_time_interval(self, selector_string):
r"""Gets the sweep time when you set the :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute
to **False**. This value is expressed in seconds.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.001.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the sweep time when you set the :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute
to **False**. This value is expressed in seconds.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_INTERVAL.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_sweep_time_interval(self, selector_string, value):
r"""Sets the sweep time when you set the :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute
to **False**. This value is expressed in seconds.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.001.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the sweep time when you set the :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute
to **False**. This value is expressed in seconds.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_INTERVAL.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_detector_type(self, selector_string):
r"""Gets the type of detector to be used.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **None**.
Refer to `Spectral Measurements Concepts
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/spectral-measurements-concepts.html>`_ topic for more information on
detector types.
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+=====================+==========================================================================================================================+
| None (0) | The detector is disabled. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Sample (1) | The middle sample in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Normal (2) | The maximum value of the samples within the bucket is detected if the signal only rises or if the signal only falls. If |
| | the signal, within a bucket, both rises and falls, then the maximum and minimum values of the samples are detected in |
| | alternate buckets. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Peak (3) | The maximum value of the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Negative Peak (4) | The minimum value of the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Average RMS (5) | The average RMS of all the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Average Voltage (6) | The average voltage of all the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Average Log (7) | The average log of all the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpDetectorType):
Specifies the type of detector to be used.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_DETECTOR_TYPE.value
)
attr_val = enums.ChpDetectorType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_detector_type(self, selector_string, value):
r"""Sets the type of detector to be used.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **None**.
Refer to `Spectral Measurements Concepts
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/spectral-measurements-concepts.html>`_ topic for more information on
detector types.
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+=====================+==========================================================================================================================+
| None (0) | The detector is disabled. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Sample (1) | The middle sample in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Normal (2) | The maximum value of the samples within the bucket is detected if the signal only rises or if the signal only falls. If |
| | the signal, within a bucket, both rises and falls, then the maximum and minimum values of the samples are detected in |
| | alternate buckets. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Peak (3) | The maximum value of the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Negative Peak (4) | The minimum value of the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Average RMS (5) | The average RMS of all the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Average Voltage (6) | The average voltage of all the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Average Log (7) | The average log of all the samples in the bucket is detected. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpDetectorType, int):
Specifies the type of detector to be used.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpDetectorType else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_DETECTOR_TYPE.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_detector_points(self, selector_string):
r"""Gets the number of trace points after the detector is applied.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1001.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the number of trace points after the detector is applied.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_DETECTOR_POINTS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_detector_points(self, selector_string, value):
r"""Sets the number of trace points after the detector is applied.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1001.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the number of trace points after the detector is applied.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_DETECTOR_POINTS.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_noise_calibration_mode(self, selector_string):
r"""Gets whether the noise calibration and measurement is performed manually by the user or automatically by RFmx.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Auto**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| Manual (0) | When you set the CHP Meas Mode attribute to Calibrate Noise Floor, you can initiate instrument noise calibration for |
| | the CHP measurement manually. When you set the CHP Meas Mode attribute to Measure, you can initiate the CHP measurement |
| | manually. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Auto (1) | When you set the CHP Noise Comp Enabled attribute to True, RFmx sets Input Isolation Enabled to Enabled and calibrates |
| | the intrument noise in the current state of the instrument. RFmx then resets the Input Isolation Enabled attribute and |
| | performs the CHP measurement, including compensation for noise of the instrument. RFmx skips noise calibration in this |
| | mode if valid noise calibration data is already cached. When you set the CHP Noise Comp Enabled attribute to False, |
| | RFmx does not calibrate instrument noise and performs only the CHP measurement without compensating for the noise |
| | contribution of the instrument. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpNoiseCalibrationMode):
Specifies whether the noise calibration and measurement is performed manually by the user or automatically by RFmx.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_NOISE_CALIBRATION_MODE.value
)
attr_val = enums.ChpNoiseCalibrationMode(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_noise_calibration_mode(self, selector_string, value):
r"""Sets whether the noise calibration and measurement is performed manually by the user or automatically by RFmx.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Auto**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| Manual (0) | When you set the CHP Meas Mode attribute to Calibrate Noise Floor, you can initiate instrument noise calibration for |
| | the CHP measurement manually. When you set the CHP Meas Mode attribute to Measure, you can initiate the CHP measurement |
| | manually. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Auto (1) | When you set the CHP Noise Comp Enabled attribute to True, RFmx sets Input Isolation Enabled to Enabled and calibrates |
| | the intrument noise in the current state of the instrument. RFmx then resets the Input Isolation Enabled attribute and |
| | performs the CHP measurement, including compensation for noise of the instrument. RFmx skips noise calibration in this |
| | mode if valid noise calibration data is already cached. When you set the CHP Noise Comp Enabled attribute to False, |
| | RFmx does not calibrate instrument noise and performs only the CHP measurement without compensating for the noise |
| | contribution of the instrument. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpNoiseCalibrationMode, int):
Specifies whether the noise calibration and measurement is performed manually by the user or automatically by RFmx.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpNoiseCalibrationMode else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_CALIBRATION_MODE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_noise_calibration_averaging_auto(self, selector_string):
r"""Gets whether RFmx automatically computes the averaging count used for instrument noise calibration.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **True**.
+--------------+--------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+======================================================================================+
| False (0) | RFmx uses the averages that you set for the CHP Noise Cal Averaging Count attribute. |
+--------------+--------------------------------------------------------------------------------------+
| True (1) | RFmx uses a noise calibration averaging count of 32. |
+--------------+--------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpNoiseCalibrationAveragingAuto):
Specifies whether RFmx automatically computes the averaging count used for instrument noise calibration.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_AUTO.value,
)
attr_val = enums.ChpNoiseCalibrationAveragingAuto(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_noise_calibration_averaging_auto(self, selector_string, value):
r"""Sets whether RFmx automatically computes the averaging count used for instrument noise calibration.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **True**.
+--------------+--------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+======================================================================================+
| False (0) | RFmx uses the averages that you set for the CHP Noise Cal Averaging Count attribute. |
+--------------+--------------------------------------------------------------------------------------+
| True (1) | RFmx uses a noise calibration averaging count of 32. |
+--------------+--------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpNoiseCalibrationAveragingAuto, int):
Specifies whether RFmx automatically computes the averaging count used for instrument noise calibration.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpNoiseCalibrationAveragingAuto else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_AUTO.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_noise_calibration_averaging_count(self, selector_string):
r"""Gets the averaging count used for noise calibration when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_AUTO` attribute to **False**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 32.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the averaging count used for noise calibration when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_AUTO` attribute to **False**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_COUNT.value,
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_noise_calibration_averaging_count(self, selector_string, value):
r"""Sets the averaging count used for noise calibration when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_AUTO` attribute to **False**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 32.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the averaging count used for noise calibration when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_AUTO` attribute to **False**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_CALIBRATION_AVERAGING_COUNT.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_noise_compensation_enabled(self, selector_string):
r"""Gets whether RFmx compensates for the instrument noise when performing the measurement. To compensate for
instrument noise when performing a CHP measurement, set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_MODE` attribute to **Auto**, or set the CHP Noise
Cal Mode attribute to **Manual** and :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_MEASUREMENT_MODE` attribute to
**Measure**.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **False**.
+--------------+------------------------------+
| Name (Value) | Description |
+==============+==============================+
| False (0) | Disables noise compensation. |
+--------------+------------------------------+
| True (1) | Enables noise compensation. |
+--------------+------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpNoiseCompensationEnabled):
Specifies whether RFmx compensates for the instrument noise when performing the measurement. To compensate for
instrument noise when performing a CHP measurement, set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_MODE` attribute to **Auto**, or set the CHP Noise
Cal Mode attribute to **Manual** and :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_MEASUREMENT_MODE` attribute to
**Measure**.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_NOISE_COMPENSATION_ENABLED.value
)
attr_val = enums.ChpNoiseCompensationEnabled(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_noise_compensation_enabled(self, selector_string, value):
r"""Sets whether RFmx compensates for the instrument noise when performing the measurement. To compensate for
instrument noise when performing a CHP measurement, set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_MODE` attribute to **Auto**, or set the CHP Noise
Cal Mode attribute to **Manual** and :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_MEASUREMENT_MODE` attribute to
**Measure**.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **False**.
+--------------+------------------------------+
| Name (Value) | Description |
+==============+==============================+
| False (0) | Disables noise compensation. |
+--------------+------------------------------+
| True (1) | Enables noise compensation. |
+--------------+------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpNoiseCompensationEnabled, int):
Specifies whether RFmx compensates for the instrument noise when performing the measurement. To compensate for
instrument noise when performing a CHP measurement, set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_NOISE_CALIBRATION_MODE` attribute to **Auto**, or set the CHP Noise
Cal Mode attribute to **Manual** and :py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_MEASUREMENT_MODE` attribute to
**Measure**.
Refer to the measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpNoiseCompensationEnabled else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_COMPENSATION_ENABLED.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_noise_compensation_type(self, selector_string):
r"""Gets the noise compensation type. Refer to the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Analyzer and Termination**.
+------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============================+==========================================================================================================================+
| Analyzer and Termination (0) | Compensates for noise from the analyzer and the 50 ohm termination. The measured power values are in excess of the |
| | thermal noise floor. |
+------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Analyzer Only (1) | Compensates for the analyzer noise only. |
+------------------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpNoiseCompensationType):
Specifies the noise compensation type. Refer to the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_NOISE_COMPENSATION_TYPE.value
)
attr_val = enums.ChpNoiseCompensationType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_noise_compensation_type(self, selector_string, value):
r"""Sets the noise compensation type. Refer to the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Analyzer and Termination**.
+------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============================+==========================================================================================================================+
| Analyzer and Termination (0) | Compensates for noise from the analyzer and the 50 ohm termination. The measured power values are in excess of the |
| | thermal noise floor. |
+------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Analyzer Only (1) | Compensates for the analyzer noise only. |
+------------------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpNoiseCompensationType, int):
Specifies the noise compensation type. Refer to the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpNoiseCompensationType else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NOISE_COMPENSATION_TYPE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_averaging_enabled(self, selector_string):
r"""Gets whether to enable averaging for the CHP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **False**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| False (0) | The measurement is performed on a single acquisition. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| True (1) | The CHP measurement uses the CHP Averaging Count attribute as the number of acquisitions over which the CHP measurement |
| | is averaged. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpAveragingEnabled):
Specifies whether to enable averaging for the CHP measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AVERAGING_ENABLED.value
)
attr_val = enums.ChpAveragingEnabled(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_averaging_enabled(self, selector_string, value):
r"""Sets whether to enable averaging for the CHP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **False**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| False (0) | The measurement is performed on a single acquisition. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| True (1) | The CHP measurement uses the CHP Averaging Count attribute as the number of acquisitions over which the CHP measurement |
| | is averaged. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpAveragingEnabled, int):
Specifies whether to enable averaging for the CHP measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpAveragingEnabled else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AVERAGING_ENABLED.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_averaging_count(self, selector_string):
r"""Gets the number of acquisitions used for averaging when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 10.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the number of acquisitions used for averaging when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AVERAGING_COUNT.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_averaging_count(self, selector_string, value):
r"""Sets the number of acquisitions used for averaging when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 10.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the number of acquisitions used for averaging when you set the
:py:attr:`~nirfmxspecan.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AVERAGING_COUNT.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_averaging_type(self, selector_string):
r"""Gets the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for CHP
measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **RMS**.
+--------------+-------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=============================================================================================================+
| RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Log (1) | The power spectrum is averaged in a logarithmic scale. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Scalar (2) | The square root of the power spectrum is averaged. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Min (4) | The least power in the spectrum at each frequency bin is retained from one acquisition to the next. |
+--------------+-------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpAveragingType):
Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for CHP
measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AVERAGING_TYPE.value
)
attr_val = enums.ChpAveragingType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_averaging_type(self, selector_string, value):
r"""Sets the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for CHP
measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **RMS**.
+--------------+-------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=============================================================================================================+
| RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Log (1) | The power spectrum is averaged in a logarithmic scale. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Scalar (2) | The square root of the power spectrum is averaged. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. |
+--------------+-------------------------------------------------------------------------------------------------------------+
| Min (4) | The least power in the spectrum at each frequency bin is retained from one acquisition to the next. |
+--------------+-------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpAveragingType, int):
Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for CHP
measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpAveragingType else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AVERAGING_TYPE.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_measurement_mode(self, selector_string):
r"""Gets whether the measurement calibrates the noise floor of analyzer or performs the CHP measurement. Refer to the
measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Measure**.
+---------------------------+---------------------------------------------------------------------------------------+
| Name (Value) | Description |
+===========================+=======================================================================================+
| Measure (0) | CHP measurement is performed on the acquired signal. |
+---------------------------+---------------------------------------------------------------------------------------+
| Calibrate Noise Floor (1) | Manual noise calibration of the signal analyzer is performed for the CHP measurement. |
+---------------------------+---------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpMeasurementMode):
Specifies whether the measurement calibrates the noise floor of analyzer or performs the CHP measurement. Refer to the
measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_MODE.value
)
attr_val = enums.ChpMeasurementMode(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_measurement_mode(self, selector_string, value):
r"""Sets whether the measurement calibrates the noise floor of analyzer or performs the CHP measurement. Refer to the
measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Measure**.
+---------------------------+---------------------------------------------------------------------------------------+
| Name (Value) | Description |
+===========================+=======================================================================================+
| Measure (0) | CHP measurement is performed on the acquired signal. |
+---------------------------+---------------------------------------------------------------------------------------+
| Calibrate Noise Floor (1) | Manual noise calibration of the signal analyzer is performed for the CHP measurement. |
+---------------------------+---------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpMeasurementMode, int):
Specifies whether the measurement calibrates the noise floor of analyzer or performs the CHP measurement. Refer to the
measurement guidelines section in the `Noise Compensation Algorithm
<www.ni.com/docs/en-US/bundle/rfmx-specan/page/noise-compensation-algorithm.html>`_ topic for more information.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpMeasurementMode else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_MODE.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_fft_window(self, selector_string):
r"""Gets the FFT window type to use to reduce spectral leakage.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Flat Top**.
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+=====================+==========================================================================================================================+
| None (0) | Analyzes transients for which duration is shorter than the window length. You can also use this window type to separate |
| | two tones with frequencies close to each other but with almost equal amplitudes. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Flat Top (1) | Measures single-tone amplitudes accurately. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Hanning (2) | Analyzes transients for which duration is longer than the window length. You can also use this window type to provide |
| | better frequency resolution for noise measurements. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Hamming (3) | Analyzes closely-spaced sine waves. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Gaussian (4) | Provides a good balance of spectral leakage, frequency resolution, and amplitude attenuation. Hence, this windowing is |
| | useful for time-frequency analysis. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Blackman (5) | Analyzes single tone because it has a low maximum side lobe level and a high side lobe roll-off rate. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Blackman-Harris (6) | Useful as a good general purpose window, having side lobe rejection greater than 90 dB and having a moderately wide |
| | main lobe. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Kaiser-Bessel (7) | Separates two tones with frequencies close to each other but with widely-differing amplitudes. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpFftWindow):
Specifies the FFT window type to use to reduce spectral leakage.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_FFT_WINDOW.value
)
attr_val = enums.ChpFftWindow(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_fft_window(self, selector_string, value):
r"""Sets the FFT window type to use to reduce spectral leakage.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Flat Top**.
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+=====================+==========================================================================================================================+
| None (0) | Analyzes transients for which duration is shorter than the window length. You can also use this window type to separate |
| | two tones with frequencies close to each other but with almost equal amplitudes. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Flat Top (1) | Measures single-tone amplitudes accurately. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Hanning (2) | Analyzes transients for which duration is longer than the window length. You can also use this window type to provide |
| | better frequency resolution for noise measurements. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Hamming (3) | Analyzes closely-spaced sine waves. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Gaussian (4) | Provides a good balance of spectral leakage, frequency resolution, and amplitude attenuation. Hence, this windowing is |
| | useful for time-frequency analysis. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Blackman (5) | Analyzes single tone because it has a low maximum side lobe level and a high side lobe roll-off rate. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Blackman-Harris (6) | Useful as a good general purpose window, having side lobe rejection greater than 90 dB and having a moderately wide |
| | main lobe. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
| Kaiser-Bessel (7) | Separates two tones with frequencies close to each other but with widely-differing amplitudes. |
+---------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpFftWindow, int):
Specifies the FFT window type to use to reduce spectral leakage.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpFftWindow else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_FFT_WINDOW.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_fft_padding(self, selector_string):
r"""Gets the factor by which the time-domain waveform is zero-padded before fast Fourier transform (FFT). The FFT size
is given by the following formula:
waveform size * padding
This attribute is used only when the acquisition span is less than the device instantaneous bandwidth of the
device.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is -1.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the factor by which the time-domain waveform is zero-padded before fast Fourier transform (FFT). The FFT size
is given by the following formula:
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_FFT_PADDING.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_fft_padding(self, selector_string, value):
r"""Sets the factor by which the time-domain waveform is zero-padded before fast Fourier transform (FFT). The FFT size
is given by the following formula:
waveform size * padding
This attribute is used only when the acquisition span is less than the device instantaneous bandwidth of the
device.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is -1.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the factor by which the time-domain waveform is zero-padded before fast Fourier transform (FFT). The FFT size
is given by the following formula:
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string, attributes.AttributeID.CHP_FFT_PADDING.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_amplitude_correction_type(self, selector_string):
r"""Gets whether the amplitude of the frequency bins, used in the measurement, is corrected for external attenuation
at the RF center frequency, or at the individual frequency bins. Use the
:py:meth:`nirfmxinstr.session.Session.configure_external_attenuation_table` method to configure the external
attenuation table.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **RF Center Frequency**.
+----------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+============================+==========================================================================================================================+
| RF Center Frequency (0) | All the frequency bins in the spectrum are compensated with a single external attenuation value that corresponds to the |
| | RF center frequency. |
+----------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Spectrum Frequency Bin (1) | An individual frequency bin in the spectrum is compensated with the external attenuation value corresponding to that |
| | frequency. |
+----------------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChpAmplitudeCorrectionType):
Specifies whether the amplitude of the frequency bins, used in the measurement, is corrected for external attenuation
at the RF center frequency, or at the individual frequency bins. Use the
:py:meth:`nirfmxinstr.session.Session.configure_external_attenuation_table` method to configure the external
attenuation table.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_AMPLITUDE_CORRECTION_TYPE.value
)
attr_val = enums.ChpAmplitudeCorrectionType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_amplitude_correction_type(self, selector_string, value):
r"""Sets whether the amplitude of the frequency bins, used in the measurement, is corrected for external attenuation
at the RF center frequency, or at the individual frequency bins. Use the
:py:meth:`nirfmxinstr.session.Session.configure_external_attenuation_table` method to configure the external
attenuation table.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **RF Center Frequency**.
+----------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+============================+==========================================================================================================================+
| RF Center Frequency (0) | All the frequency bins in the spectrum are compensated with a single external attenuation value that corresponds to the |
| | RF center frequency. |
+----------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Spectrum Frequency Bin (1) | An individual frequency bin in the spectrum is compensated with the external attenuation value corresponding to that |
| | frequency. |
+----------------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChpAmplitudeCorrectionType, int):
Specifies whether the amplitude of the frequency bins, used in the measurement, is corrected for external attenuation
at the RF center frequency, or at the individual frequency bins. Use the
:py:meth:`nirfmxinstr.session.Session.configure_external_attenuation_table` method to configure the external
attenuation table.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.ChpAmplitudeCorrectionType else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_AMPLITUDE_CORRECTION_TYPE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_all_traces_enabled(self, selector_string):
r"""Gets whether to enable the traces to be stored and retrieved after performing the CHP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is FALSE.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (bool):
Specifies whether to enable the traces to be stored and retrieved after performing the CHP measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_ALL_TRACES_ENABLED.value
)
attr_val = bool(attr_val)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_all_traces_enabled(self, selector_string, value):
r"""Sets whether to enable the traces to be stored and retrieved after performing the CHP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is FALSE.
Args:
selector_string (string):
Pass an empty string.
value (bool):
Specifies whether to enable the traces to be stored and retrieved after performing the CHP measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_ALL_TRACES_ENABLED.value,
int(value),
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_number_of_analysis_threads(self, selector_string):
r"""Gets the maximum number of threads used for parallelism for CHP measurement.
The number of threads can range from 1 to the number of physical cores. The number of threads you set may not
be used in calculations. The actual number of threads used depends on the problem size, system resources, data
availability, and other considerations.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the maximum number of threads used for parallelism for CHP measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_ANALYSIS_THREADS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_number_of_analysis_threads(self, selector_string, value):
r"""Sets the maximum number of threads used for parallelism for CHP measurement.
The number of threads can range from 1 to the number of physical cores. The number of threads you set may not
be used in calculations. The actual number of threads used depends on the problem size, system resources, data
availability, and other considerations.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the maximum number of threads used for parallelism for CHP measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.CHP_NUMBER_OF_ANALYSIS_THREADS.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def validate_noise_calibration_data(self, selector_string):
r"""Indicates whether calibration data is valid for the configuration specified by the signal name in the **Selector
string** parameter.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
Returns:
Tuple (noise_calibration_data_valid, error_code):
noise_calibration_data_valid (enums.ChpNoiseCalibrationDataValid):
This parameter returns whether the calibration data is valid.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| False (0) | Returns false if the calibration data is not present for the specified configuration or if the difference between the |
| | current device temperature and the calibration temperature exceeds the [-5 °C, 5 °C] range. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| True (1) | Returns true if the calibration data is present for the configuration specified by the signal name in the Selector |
| | string parameter. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
noise_calibration_data_valid, error_code = (
self._interpreter.chp_validate_noise_calibration_data(updated_selector_string)
)
finally:
self._session_function_lock.exit_read_lock()
return noise_calibration_data_valid, error_code